We have established a product research and development center to lay a solid foundation for continuous improvement of ercp balloon, aortic occlusion balloon catheter, microtech stent. As operation principle is 'be market-oriented, good faith as principle, win-win as objective', holding on 'customer first, quality assurance, service first' as our purpose, dedicated to provide the original quality and create excellence service. We aim for quality growth, provide efficient value-added services to our partners and customers, and bring satisfactory returns to our shareholders. In the continuous development and growth of the company, we always adhere to the customer first, integrity first, mutual benefit and win-win purpose.
Product Model
| Model | Order Number | Working Length(mm) | Clip opening(mm) | Claw Angle℃ | Rotatable |
S | MD-S-HR-195-9-135-Y | 1950 | 9 | 135 | YES |
MD-S-HR-230-9-135-Y | 2300 | 9 | 135 | YES | |
C | MD-C-HR-195-13-135-Y | 1950 | 13 | 135 | YES |
MD-C-HR-230-13-135-Y | 2300 | 13 | 135 | YES | |
A | MD-L-HR-195-16-135-Y | 1950 | 16 | 135 | YES |
MD-L-HR-230-16-135-Y | 2300 | 16 | 135 | YES |
Indication
Disposable GI Hemoclip is used in the digestive tract under endoscope placed within the clip, for use in GI bleeding and endoscopic marking.
Features
Short left body parts, make GI surgery safer.
Clip large opening designed;
Can be repeated opening and closing;
360-degree rotatable;
Instructions for Use
1. Check whether the package is intact. Remove the Hemoclip from the package.
2. Pull back the Slide Handle gently, ensure the Clip is in self-locking state, remove the Protective Sheath.
3. Ensure the Clip is in self-locking state, carefully insert the device through the endoscope channel, and gradually deliver the device with each 2 to 3 cm forward.
4. When the device arrives at the target position, push the Slider Handle forward to open the clip. The clip open may have a resistant force since it has to free from the self-locking state.
5. Hold the End Cap by the other hand, rotate the Thumb Ring to adjust the angle and ensure it can clamp the tissue. In order to obtain a better rotation, move the slider Ring distally.
6. When satisfied with the clip position, close the clip against the tissue by pull the Slider Handle back toward the Thumb Ring. Feel a resistance in handle indicate the clip is deployed.
7. The device can be re-open and repositioned before deployed.