We have further increased the manufacturing and sales of various new products, ensuring that our endoscopic extraction balloon, Disposable Guidewire, Pta Balloon Catheter is at an advanced level in the industry, and achieving the strategic goal of sustainable development. For customers, we will strengthen market awareness, adhere to customer orientation, meet their needs, and strive to exceed their expectations. The company will continue to adhere to prevention-oriented, continuous improvement, continuous optimization of resource allocation, to provide customers with satisfactory products and services.
Product Model
| Model | Order Number | Working Length(mm) | Clip opening(mm) | Claw Angle℃ | Rotatable |
S | MD-S-HR-195-9-135-Y | 1950 | 9 | 135 | YES |
MD-S-HR-230-9-135-Y | 2300 | 9 | 135 | YES | |
C | MD-C-HR-195-13-135-Y | 1950 | 13 | 135 | YES |
MD-C-HR-230-13-135-Y | 2300 | 13 | 135 | YES | |
A | MD-A-HR-195-16-135-Y | 1950 | 16 | 135 | YES |
MD-A-HR-230-16-135-Y | 2300 | 16 | 135 | YES |
Indication
Rotatable hemoclip is Used in the digestive tract under endoscope placed within the clip, for use in Gastrointestinal marking or hemostatic treatment.
The rotatable hemoclips enable faster and more accurate placement.
Features
360-Degree rotatable, convenient clinical operation, offering a precise placement;
Repeated opening and closing clips achieves repositioning;
Clip large opening designed, capable of fulfilling various clinical treatment demands;
Smooth coating design to avoid damage to the instrument channel of the endoscope;
Ready-to-use, which is essential for emergency bleeding situations.
Precautions
1. Do not use if the package is open or damaged when received.
2. Prior to using the device, read carefully the instructions manual. Select the endoscope with the channel size that is compatible with the device.
3. Inspect the device before using this device to ensure it is free of kink and damage.
4. DO NOT use if any abnormality is found.
5. The procedure should be performed under direct endoscopic visualization.
6. This device cannot be used for other intended uses.
7. This device is sterile and intended for single use. It must be destroyed after use per institutional guidelines for biohazardous medical waste.
8. This device must be used by trained clinicians.
9. After use, dispose of product and packaging in accordance with hospital, administrative and/or local government policy.