Our filiform urethral dilator, urology escape basket, endoscope sponge is full of varieties, novel styles and superior performance, which is well received by customers. We listen attentively to the feedback from our customers and provide instant replies. We enhance the competitiveness of our enterprise through science and technology, and our business performance keeps growing with remarkable economic and social benefits. As the main body of the market economy, honesty is the way for enterprises to set up their business and the foundation for their development, which has a great responsibility for standardizing the order of the market economy. We cultivate and build the core competitiveness of enterprises, and actively promote the adjustment of industrial structure.
Product Model
| Model | Order Number | Working Length(mm) | Clip opening(mm) | Claw Angle℃ | Rotatable |
S | MD-S-HR-195-9-135-Y | 1950 | 9 | 135 | YES |
MD-S-HR-230-9-135-Y | 2300 | 9 | 135 | YES | |
G | MD-G-HR-195-12-135-Y | 1950 | 12 | 135 | YES |
MD-G-HR-230-12-135-Y | 2300 | 12 | 135 | YES | |
C | MD-C-HR-195-13-135-Y | 1950 | 13 | 135 | YES |
MD-C-HR-230-13-135-Y | 2300 | 13 | 135 | YES | |
L | MD-L-HR-195-15-135-Y | 1950 | 15 | 135 | YES |
MD-L-HR-230-15-135-Y | 2300 | 15 | 135 | YES | |
A | MD-A-HR-195-15-135-Y | 1950 | 16 | 135 | YES |
MD-A-HR-230-15-135-Y | 2300 | 16 | 135 | YES |
Brand
MEDNOVA
OEM available
Certificates
ISO/CE/FDA/CFDA/Russia Registration etc.
Indication
MEDNOVA hemoclip is indicated for clip placement within the Gastro-intestinal (GI) tract for the purpose of:
1. Endoscopic marking,
2. Hemostasis for:
Mucosal/Sub-mucosal defect <3 cm;
Bleeding ulcers;
Arteries <2mm;
Polyps <1.5cm in diameter;
Diverticula in the colon
3. Anchoring to affix jejuna feeding tubes to the wall of the small bowel;
4. As a supplementary method, closure of GI tract luminal.
Features
All-in-one design of gastrointestinal clip;
Short left body parts, make surgery safer;
Clip is large opening designed, capable of grasp a sizeable amount of tissue;
Can be repeated opening and closing, may achieve repositioning;
360-Degree rotatable, convenient clinical operation;
Variety spans of 9mm,12mm,13mm, 15mm and 16mm,which fully meet the different requirements.
MR Conditional
The vitro simulative test on single sterile repositionable hemoclip demonstrate that, according to the ASTM F2503 standard, patients with one clip or multiple dispersive clips or even multiple centralized clips which not touch each other, could get safely scanned under magnetic resonance parameters as MR instructions.
Caution
If there are more than one of these clips in a single location in the body and multiple clips touch each other, the consequences of MRI scanning have not been adequately studied. We suggest performing MRI scan after clips getting off along with the connective tissues.