Skilled professional knowledge, strong sense of service, to meet the service needs of customers for aortic occlusion balloon catheter, High Pressure Balloon Catheter, 3V Sphincterotomes. We will make use of abundant resources, excellent talents, and satisfactory after-sales service; we will continue to take quality first, reputation first, and service satisfaction as our tenet, and sincerely cooperate with you to create a better future! We win the trust of customers with high quality products, first-class service and reasonable price. We provide superior material and spiritual conditions for our employees to work and live happily, create an excellent platform to use the right people in the right positions, and enable our employees to give full play to their talents. While we use advanced technology to provide customers with products, we also actively assume social responsibilities and have been widely recognized by the society.
Product Model
| Model | Order Number | Working Length(mm) | Clip opening(mm) | Claw Angle℃ | Rotatable |
S | MD-S-HR-195-9-135-Y | 1950 | 9 | 135 | YES |
MD-S-HR-230-9-135-Y | 2300 | 9 | 135 | YES | |
C | MD-C-HR-195-13-135-Y | 1950 | 13 | 135 | YES |
MD-C-HR-230-13-135-Y | 2300 | 13 | 135 | YES | |
A | MD-L-HR-195-16-135-Y | 1950 | 16 | 135 | YES |
MD-L-HR-230-16-135-Y | 2300 | 16 | 135 | YES |
Indication
Disposable GI Hemoclip is used in the digestive tract under endoscope placed within the clip, for use in GI bleeding and endoscopic marking.
Features
Short left body parts, make GI surgery safer.
Clip large opening designed;
Can be repeated opening and closing;
360-degree rotatable;
Instructions for Use
1. Check whether the package is intact. Remove the Hemoclip from the package.
2. Pull back the Slide Handle gently, ensure the Clip is in self-locking state, remove the Protective Sheath.
3. Ensure the Clip is in self-locking state, carefully insert the device through the endoscope channel, and gradually deliver the device with each 2 to 3 cm forward.
4. When the device arrives at the target position, push the Slider Handle forward to open the clip. The clip open may have a resistant force since it has to free from the self-locking state.
5. Hold the End Cap by the other hand, rotate the Thumb Ring to adjust the angle and ensure it can clamp the tissue. In order to obtain a better rotation, move the slider Ring distally.
6. When satisfied with the clip position, close the clip against the tissue by pull the Slider Handle back toward the Thumb Ring. Feel a resistance in handle indicate the clip is deployed.
7. The device can be re-open and repositioned before deployed.