Our company adheres to the principle of being a down-to-earth person and doing things seriously. We devote ourselves to the research and development and production of oval cup biopsy forcep, endoscopic irrigation pump, Disposable Gi Hemoclip and take the first-class products as the cornerstone to prove our strength. The implementation of our quality first concept is conducive to the sustainable development of our company and is of great significance to the realization of our overall development strategy. We are committed to new product development, quality improvement and perfect after-sales service. "Persistently strive for better" is our aim! Our company provides improved customized support services, with a professional after-sales team to respond to customer inquiries online. We have experienced the impact and challenge of internal and external, as well as the severe test of the business environment.
Product Model
| Model | Order Number | Working Length(mm) | Clip opening(mm) | Claw Angle℃ | Rotatable |
S | MD-S-HR-195-9-135-Y | 1950 | 9 | 135 | YES |
MD-S-HR-230-9-135-Y | 2300 | 9 | 135 | YES | |
G | MD-G-HR-195-12-135-Y | 1950 | 12 | 135 | YES |
MD-G-HR-230-12-135-Y | 2300 | 12 | 135 | YES | |
C | MD-C-HR-195-13-135-Y | 1950 | 13 | 135 | YES |
MD-C-HR-230-13-135-Y | 2300 | 13 | 135 | YES | |
L | MD-L-HR-195-15-135-Y | 1950 | 15 | 135 | YES |
MD-L-HR-230-15-135-Y | 2300 | 15 | 135 | YES | |
A | MD-A-HR-195-15-135-Y | 1950 | 16 | 135 | YES |
MD-A-HR-230-15-135-Y | 2300 | 16 | 135 | YES |
Brand
MEDNOVA
OEM available
Certificates
ISO/CE/FDA/CFDA/Russia Registration etc.
Indication
MEDNOVA hemoclip is indicated for clip placement within the Gastro-intestinal (GI) tract for the purpose of:
1. Endoscopic marking,
2. Hemostasis for:
Mucosal/Sub-mucosal defect <3 cm;
Bleeding ulcers;
Arteries <2mm;
Polyps <1.5cm in diameter;
Diverticula in the colon
3. Anchoring to affix jejuna feeding tubes to the wall of the small bowel;
4. As a supplementary method, closure of GI tract luminal.
Features
All-in-one design of gastrointestinal clip;
Short left body parts, make surgery safer;
Clip is large opening designed, capable of grasp a sizeable amount of tissue;
Can be repeated opening and closing, may achieve repositioning;
360-Degree rotatable, convenient clinical operation;
Variety spans of 9mm,12mm,13mm, 15mm and 16mm,which fully meet the different requirements.
MR Conditional
The vitro simulative test on single sterile repositionable hemoclip demonstrate that, according to the ASTM F2503 standard, patients with one clip or multiple dispersive clips or even multiple centralized clips which not touch each other, could get safely scanned under magnetic resonance parameters as MR instructions.
Caution
If there are more than one of these clips in a single location in the body and multiple clips touch each other, the consequences of MRI scanning have not been adequately studied. We suggest performing MRI scan after clips getting off along with the connective tissues.


[[ContDescription]]
Hot Tags: hemoclip for gastrointestinal endoscopy, China, suppliers, manufacturers, factory, wholesale, cheap, Bilateral Ureteral Stent, roth net retrieval device, urology sensor guidewire, Esd Knife, extraction balloon, endoscopic insufflator system