We believe that multiple green innovations of multiple oval cup biopsy forcep, endoscopic dilatation balloon, bite block dental can drive the continuous product green innovation activities of enterprises. Our company takes cultivating talents as the goal, and truly achieves the goal of satisfying customers, serving the public, pursuing quality and co creation and development. We take human resource strategy and planning as our guide to continuously improve the level of human resource management and the quality of our talents.
Product Model
| Model | Order Number | Working Length(mm) | Clip opening(mm) | Claw Angle℃ | Rotatable |
S | MD-S-HR-195-9-135-Y | 1950 | 9 | 135 | YES |
MD-S-HR-230-9-135-Y | 2300 | 9 | 135 | YES | |
C | MD-C-HR-195-13-135-Y | 1950 | 13 | 135 | YES |
MD-C-HR-230-13-135-Y | 2300 | 13 | 135 | YES | |
A | MD-A-HR-195-16-135-Y | 1950 | 16 | 135 | YES |
MD-A-HR-230-16-135-Y | 2300 | 16 | 135 | YES |
Indication
Rotatable hemoclip is Used in the digestive tract under endoscope placed within the clip, for use in Gastrointestinal marking or hemostatic treatment.
The rotatable hemoclips enable faster and more accurate placement.
Features
360-Degree rotatable, convenient clinical operation, offering a precise placement;
Repeated opening and closing clips achieves repositioning;
Clip large opening designed, capable of fulfilling various clinical treatment demands;
Smooth coating design to avoid damage to the instrument channel of the endoscope;
Ready-to-use, which is essential for emergency bleeding situations.
Precautions
1. Do not use if the package is open or damaged when received.
2. Prior to using the device, read carefully the instructions manual. Select the endoscope with the channel size that is compatible with the device.
3. Inspect the device before using this device to ensure it is free of kink and damage.
4. DO NOT use if any abnormality is found.
5. The procedure should be performed under direct endoscopic visualization.
6. This device cannot be used for other intended uses.
7. This device is sterile and intended for single use. It must be destroyed after use per institutional guidelines for biohazardous medical waste.
8. This device must be used by trained clinicians.
9. After use, dispose of product and packaging in accordance with hospital, administrative and/or local government policy.


[[ContDescription]]
Hot Tags: rotatable hemoclip clip, China, suppliers, manufacturers, factory, wholesale, cheap, Polypectomy Snare, endoscopic irrigation pump, otw dilator, surgical cotton bud, Endoscopic Guidewire, ercp guidewire