We recognize the need to develop high-tech double pigtail ureteral stent, ercp guidewire, monorail balloon catheter to enhance our core competitiveness in today's era of innovation. Our company takes 'customer first, keep improving, continuous improvement' as its own quality policy. Quality is the first step to establish a brand image. Only when the quality is good, customers will be willing to spend. We seriously promise that we provide all the customers with the best quality products, the most competitive prices and the most prompt delivery. We have introduced advanced technology from similar products at home and abroad, and trained a group of skilled and dedicated production, manufacturing and construction personnel.
Product Model
| Model | Order Number | Working Length(mm) | Clip opening(mm) | Claw Angle℃ | Rotatable |
S | MD-S-HR-195-9-135-Y | 1950 | 9 | 135 | YES |
MD-S-HR-230-9-135-Y | 2300 | 9 | 135 | YES | |
C | MD-C-HR-195-13-135-Y | 1950 | 13 | 135 | YES |
MD-C-HR-230-13-135-Y | 2300 | 13 | 135 | YES | |
A | MD-L-HR-195-16-135-Y | 1950 | 16 | 135 | YES |
MD-L-HR-230-16-135-Y | 2300 | 16 | 135 | YES |
Indication
Disposable GI Hemoclip is used in the digestive tract under endoscope placed within the clip, for use in GI bleeding and endoscopic marking.
Features
Short left body parts, make GI surgery safer.
Clip large opening designed;
Can be repeated opening and closing;
360-degree rotatable;
Instructions for Use
1. Check whether the package is intact. Remove the Hemoclip from the package.
2. Pull back the Slide Handle gently, ensure the Clip is in self-locking state, remove the Protective Sheath.
3. Ensure the Clip is in self-locking state, carefully insert the device through the endoscope channel, and gradually deliver the device with each 2 to 3 cm forward.
4. When the device arrives at the target position, push the Slider Handle forward to open the clip. The clip open may have a resistant force since it has to free from the self-locking state.
5. Hold the End Cap by the other hand, rotate the Thumb Ring to adjust the angle and ensure it can clamp the tissue. In order to obtain a better rotation, move the slider Ring distally.
6. When satisfied with the clip position, close the clip against the tissue by pull the Slider Handle back toward the Thumb Ring. Feel a resistance in handle indicate the clip is deployed.
7. The device can be re-open and repositioned before deployed.