We always focus on product development and technological innovation, and design our polyp retrieval net, co2 insufflator, 3 wire spiral retrieval basket with scientific and stable concepts. With the increasingly fierce market competition, our company has higher and higher requirements for the comprehensive quality and professional knowledge of employees. Centralized fund management can effectively reduce the cost of capital, enhance the value of enterprises and control the risk of capital.
Product Model
| Model | Order Number | Working Length(mm) | Clip opening(mm) | Claw Angle℃ | Rotatable |
S | MD-S-HR-195-9-135-Y | 1950 | 9 | 135 | YES |
MD-S-HR-230-9-135-Y | 2300 | 9 | 135 | YES | |
C | MD-C-HR-195-13-135-Y | 1950 | 13 | 135 | YES |
MD-C-HR-230-13-135-Y | 2300 | 13 | 135 | YES | |
A | MD-A-HR-195-16-135-Y | 1950 | 16 | 135 | YES |
MD-A-HR-230-16-135-Y | 2300 | 16 | 135 | YES |
Indication
Rotatable hemoclip is Used in the digestive tract under endoscope placed within the clip, for use in Gastrointestinal marking or hemostatic treatment.
The rotatable hemoclips enable faster and more accurate placement.
Features
360-Degree rotatable, convenient clinical operation, offering a precise placement;
Repeated opening and closing clips achieves repositioning;
Clip large opening designed, capable of fulfilling various clinical treatment demands;
Smooth coating design to avoid damage to the instrument channel of the endoscope;
Ready-to-use, which is essential for emergency bleeding situations.
Precautions
1. Do not use if the package is open or damaged when received.
2. Prior to using the device, read carefully the instructions manual. Select the endoscope with the channel size that is compatible with the device.
3. Inspect the device before using this device to ensure it is free of kink and damage.
4. DO NOT use if any abnormality is found.
5. The procedure should be performed under direct endoscopic visualization.
6. This device cannot be used for other intended uses.
7. This device is sterile and intended for single use. It must be destroyed after use per institutional guidelines for biohazardous medical waste.
8. This device must be used by trained clinicians.
9. After use, dispose of product and packaging in accordance with hospital, administrative and/or local government policy.