We are proud of the high customer satisfaction and wide acceptance due to our persistent pursuit of high quality both on product and service for forcep with spike, neuro balloon catheter, zero tip stone basket. We will continue to make every effort to seize the opportunity and grasp the current good momentum of industry development. Our company upholds the business philosophy of 'expanding the common development space and advocating the concept of profit sharing', "Integrity" as a core value requires us to be honest and law-abiding in our work, to treat everyone sincerely, and to face every matter and every problem honestly. The goal of the enterprise is the hope and bright future of the enterprise, which is the root of the survival and development of the enterprise.
Product Model
| Model | Order Number | Working Length(mm) | Clip opening(mm) | Claw Angle℃ | Rotatable |
S | MD-S-HR-195-9-135-Y | 1950 | 9 | 135 | YES |
MD-S-HR-230-9-135-Y | 2300 | 9 | 135 | YES | |
G | MD-G-HR-195-12-135-Y | 1950 | 12 | 135 | YES |
MD-G-HR-230-12-135-Y | 2300 | 12 | 135 | YES | |
C | MD-C-HR-195-13-135-Y | 1950 | 13 | 135 | YES |
MD-C-HR-230-13-135-Y | 2300 | 13 | 135 | YES | |
L | MD-L-HR-195-15-135-Y | 1950 | 15 | 135 | YES |
MD-L-HR-230-15-135-Y | 2300 | 15 | 135 | YES | |
A | MD-A-HR-195-15-135-Y | 1950 | 16 | 135 | YES |
MD-A-HR-230-15-135-Y | 2300 | 16 | 135 | YES |
Brand
MEDNOVA
OEM available
Certificates
ISO/CE/FDA/CFDA/Russia Registration etc.
Indication
MEDNOVA hemoclip is indicated for clip placement within the Gastro-intestinal (GI) tract for the purpose of:
1. Endoscopic marking,
2. Hemostasis for:
Mucosal/Sub-mucosal defect <3 cm;
Bleeding ulcers;
Arteries <2mm;
Polyps <1.5cm in diameter;
Diverticula in the colon
3. Anchoring to affix jejuna feeding tubes to the wall of the small bowel;
4. As a supplementary method, closure of GI tract luminal.
Features
All-in-one design of gastrointestinal clip;
Short left body parts, make surgery safer;
Clip is large opening designed, capable of grasp a sizeable amount of tissue;
Can be repeated opening and closing, may achieve repositioning;
360-Degree rotatable, convenient clinical operation;
Variety spans of 9mm,12mm,13mm, 15mm and 16mm,which fully meet the different requirements.
MR Conditional
The vitro simulative test on single sterile repositionable hemoclip demonstrate that, according to the ASTM F2503 standard, patients with one clip or multiple dispersive clips or even multiple centralized clips which not touch each other, could get safely scanned under magnetic resonance parameters as MR instructions.
Caution
If there are more than one of these clips in a single location in the body and multiple clips touch each other, the consequences of MRI scanning have not been adequately studied. We suggest performing MRI scan after clips getting off along with the connective tissues.


[[ContDescription]]
Hot Tags: hemoclip for gastrointestinal endoscopy, China, suppliers, manufacturers, factory, wholesale, cheap, Laparoscopic Grasping Forcep, endoscopic clip, Urology Stone Retrieval Basket, Colonoscopy Cold Snare, Disposable Cytology Brush, Endoscope Flush Knife